AQUASNAP® 30RAP
AQUASNAP® 30RAP
AQUASNAP® 30RAP
Online Quotation
Online Quotation
This product requires a custom quote to ensure it meets your specific needs. Call us now to discuss your requirements and receive a personalized quote from our friendly sales team!
- Description
- Additional Details
The AquaSnap 30RAP chiller is an effective all-in-one package that is easy to install and own. The chiller costs less to purchase and install than other chillers in its class, and operates quietly and efficiently. Value-added features include rotary scroll compression with optional digital compressor (010 to 090 units), Puron refrigerant (R-410A), a low-sound AeroAcoustic™ fan system, easy to use ComfortLink™ controls, microchannel condenser coil technology, optional integrated hydronic pump package, and an accessory fluid storage tank (sizes 010-060 only).
Performance Features
Full-load EER values up to 10.5 and IPLV values up to 15.8
ASHRAE 90.1 compliant / AHRI 550/590 certified
High-efficiency rotary scroll compressors including digital compressor unloading (factory-installed option for 010-090 units)
Standard uncoated or optional e-coated Novation® microchannel heat exchanger (MCHX) condenser coils (factory-installed option)
Hydronic pump package (factory-installed option) with optional VFD on sizes 070-150
Operation from -20 to 120 F ambient temperature (factory-installed option or field-installed accessory on sizes 018-150 with low ambient head pressure control)
Reliability Features
ETL (and ETL, Canada) listed
Galvanized steel cabinet with baked enamel powder or pre-painted finish on exterior panels passes 500-hour salt-spray test in accordance with the ASTM B-117 Standard
High and low-pressure protection/compressor overload protection
Self-contained 24-v CCN (Carrier Comfort Network™) controls including transformer
Hermetic scroll compressors and outdoor fan circuits are protected by circuit breakers or fuses
EXV (electronic expansion valve)
Maintenance Features
Over 15 diagnostic functions
Permanently lubricated fan motor bearings
Microchannel condenser coils offer simplified cleaning
Installation Features
Factory-charged with Puron refrigerant (R-410A)
All-in-one package
Single-point electrical connection available on all sizes. Dual point electrical connection available on sizes 070-150
Integral control transformer
Fluid loop storage tank designed to fit directly under unit (field-installed accessory on sizes 010-060)
On-the-ground or rooftop installation
Standard Warranty
3 year coil parts only on Novation microchannel heat exchanger
One year from start-up or 18 months from shipment on all other parts
Extended warranty packages available
Factory Installed Options
Hydronic pump package
Condenser coil options:
Microchannel:
Non-coated
E-coated
Aluminum fins (available on 070-150):
Non-coated
Pre-coated
E-coated
Copper fins (available on 070-150):
Non-coated
E-coated
Hot gas bypass (not available on sizes 010 and 015)
Digital compressor (sizes 010-090)
Non-fused disconnect (not available with dual point power or 208/230 V on sizes 100-150)
Value sound fans
Compressor sound blankets
Ultra-low sound
Security grilles/hail guards
Alternate packaging options
High short circuit current rating (not available with dual point power)
BACnet Communication
Motormaster® V low ambient control
Freeze protection (cooler heater)
Energy management module
GFI convenience outlet
Fluid loop expansion tank (sizes 010-060) and circuit setter provided with optional pump package
Field-Installed Accessories
Fluid loop storage tank (sizes 010-060)
Vibration isolation pads
Chillervisor System Manager III
Motormaster V low ambient control
Remote enhanced display
Energy management module
Navigator display
Touch Pilot display
BACnet translator control
LON translator control
Low ambient head pressure control(field-installed accessory)
30RAP AHRI* Capacity Ratings
Size | Capacity | Compressor Power Input (kW) |
Fan Power (kW) |
Total Power (kW) |
Full Load | IPLV | |||
---|---|---|---|---|---|---|---|---|---|
Tons | kW | EER | COP | EER | COP | ||||
010 | 10.5 | 36.8 | 10.7 | 1.2 | 12.0 | 10.5 | 3.1 | 14.2 | 4.2 |
015 | 14.0 | 49.2 | 15.6 | 1.3 | 16.8 | 10.0 | 2.9 | 13.2 | 3.9 |
018 | 16.1 | 56.6 | 15.6 | 3.0 | 8.6 | 10.4 | 3.0 | 14.5 | 4.2 |
020 | 18.8 | 66.1 | 19.1 | 2.9 | 21.9 | 10.3 | 3.0 | 14.5 | 4.2 |
025 | 23.4 | 82.3 | 24.5 | 2.8 | 27.4 | 10.3 | 3.0 | 15.3 | 4.5 |
030 | 27.6 | 97.1 | 30.9 | 2.7 | 33.6 | 9.9 | 2.9 | 14.8 | 4.3 |
035 | 34.4 | 121.0 | 35.9 | 3.8 | 39.7 | 10.4 | 3.0 | 14.9 | 4.4 |
040 | 38.9 | 136.8 | 42.3 | 3.8 | 46.1 | 10.1 | 3.0 | 15.3 | 4.5 |
050 | 47.3 | 166.3 | 53.1 | 3.8 | 57.0 | 10.0 | 2.9 | 14.7 | 4.3 |
055 | 51.8 | 182.2 | 56.4 | 5.3 | 61.7 | 10.1 | 3.0 | 14.6 | 4.3 |
060 | 56.0 | 196.9 | 60.8 | 5.3 | 66.2 | 10.2 | 3.0 | 14.5 | 4.2 |
070 | 68.9 | 242.3 | 75.0 | 6.4 | 81.4 | 10.2 | 3.0 | 15.2 | 4.5 |
080 | 77.4 | 272.2 | 82.3 | 7.6 | 89.9 | 10.3 | 3.0 | 15.5 | 4.5 |
090 | 84.0 | 295.4 | 90.2 | 7.6 | 97.8 | 10.3 | 3.0 | 15.8 | 4.6 |
100 | 98.0 | 344.7 | 106.8 | 8.9 | 115.7 | 10.2 | 3.0 | 15.5 | 4.5 |
115 | 111.8 | 392.2 | 120.0 | 10.2 | 130.2 | 10.3 | 3.0 | 15.6 | 4.6 |
130 | 125.1 | 440.0 | 136.8 | 11.4 | 148.2 | 10.1 | 3.0 | 15.5 | 4.5 |
150 | 136.9 | 481.5 | 149.3 | 12.7 | 162.0 | 10.1 | 3.0 | 15.2 | 4.5 |
080 | 77.4 | 272.2 | 82.3 | 7.6 | 89.9 | 10.3 | 3.0 | 15.5 | 4.5 |
Size | Cooler Flow Rate |
Cooler Water Pressure Drop |
||
---|---|---|---|---|
GPM | L/s | Ft Wg | kPa | |
010 | 25.1 | 1.6 | 13.7 | 40.9 |
015 | 33.5 | 2.1 | 15.7 | 46.8 |
018 | 38.6 | 2.4 | 15.6 | 46.5 |
020 | 45.2 | 2.9 | 14.2 | 42.4 |
025 | 56.3 | 3.6 | 17.8 | 53.1 |
030 | 66.3 | 4.2 | 20.9 | 62.3 |
035 | 82.5 | 5.2 | 13.2 | 39.4 |
040 | 93.4 | 5.9 | 13.8 | 41.2 |
050 | 113.5 | 7.2 | 19.1 | 57.0 |
055 | 124.2 | 7.8 | 17.6 | 52.5 |
060 | 134.4 | 8.5 | 20.5 | 61.2 |
070 | 165.4 | 10.4 | 19.6 | 58.6 |
080 | 185.7 | 11.7 | 21.2 | 63.4 |
090 | 201.6 | 12.7 | 22.7 | 67.9 |
100 | 235.2 | 14.8 | 22.0 | 65.8 |
115 | 268.4 | 16.9 | 23.6 | 70.5 |
130 | 300.2 | 18.9 | 23.6 | 70.5 |
150 | 328.7 | 20.7 | 24.3 | 72.6 |
080 | 185.7 | 11.7 | 21.2 | 63.4 |
LEGEND
COP = Coefficient of Performance
IPLV = Integrated Part Load Value
EER = Energy Efficiency Ratio
*Air Conditioning, Heating & Refrigeration Institute
NOTES
1. Based on AHRI-550/590 standard rating conditions. Ratings are for standard chillers only. Ratings do not include options.
30RAP Weights and Dimensions
Size | Weight | Dimensions | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Standard Units | Dual Pump Units | Length | Width | Height | ||||||
lb | kg | lb | kg | in | mm | in | mm | in | mm | |
010 | 704 | 319 | 1029 | 467 | 66.5 | 1689 | 40.5 | 1029 | 66.5 | 1689 |
015 | 718 | 326 | 1043 | 473 | 66.5 | 1689 | 40.5 | 1029 | 66.5 | 1689 |
018 | 1125 | 510 | 1450 | 658 | 88.5 | 2248 | 40.5 | 1029 | 66.5 | 1689 |
020 | 1133 | 514 | 1458 | 661 | 88.5 | 2248 | 40.5 | 1029 | 66.5 | 1689 |
025 | 1242 | 564 | 1567 | 711 | 88.5 | 2248 | 40.5 | 1029 | 78.5 | 1994 |
030 | 1283 | 582 | 1608 | 729 | 88.5 | 2248 | 40.5 | 1029 | 78.5 | 1994 |
035 | 2163 | 981 | 2850 | 1293 | 88.5 | 2248 | 92.5 | 2350 | 66.5 | 1689 |
040 | 2185 | 991 | 2872 | 1303 | 88.5 | 2248 | 92.5 | 2350 | 66.5 | 1689 |
045 | 2238 | 1015 | 2925 | 1327 | 88.5 | 2248 | 92.5 | 2350 | 78.5 | 1994 |
050 | 2263 | 1026 | 2950 | 1338 | 88.5 | 2248 | 92.5 | 2350 | 78.5 | 1994 |
060 | 2375 | 1077 | 3062 | 1389 | 88.5 | 2248 | 92.5 | 2350 | 78.5 | 1994 |
070 | 3410 | 1547 | 4092 | 1856 | 150.6 | 3826 | 88.0 | 2236 | 77.8 | 1976 |
080 | 3641 | 1652 | 4390 | 1991 | 150.6 | 3826 | 88.0 | 2236 | 77.8 | 1976 |
090 | 3697 | 1677 | 4411 | 2001 | 150.6 | 3826 | 88.0 | 2236 | 77.8 | 1976 |
100 | 4690 | 2127 | 5374 | 2438 | 191.5 | 4864 | 88.0 | 2236 | 77.8 | 1976 |
115 | 5008 | 2272 | 5692 | 2582 | 191.5 | 4864 | 88.0 | 2236 | 77.8 | 1976 |
130 | 6451 | 2926 | 7135 | 3236 | 232.0 | 5893 | 88.0 | 2236 | 77.8 | 1976 |
150 | 6938 | 3147 | 7622 | 3457 | 232.0 | 5893 | 88.0 | 2236 | 77.8 | 1976 |