AQUASNAP® 30MP
AQUASNAP® 30MP
AQUASNAP® 30MP
Online Quotation
Online Quotation
This product requires a custom quote to ensure it meets your specific needs. Call us now to discuss your requirements and receive a personalized quote from our friendly sales team!
- Description
- Additional Details
AquaSnap® 30MP packaged liquid and condenserless chillers feature a compact modular design that makes them ideal for easy replacement, retrofit, or new construction applications.
30MPA - Condenserless Chiller
30MPW - Packaged Chiller
Performance Features
ASHRAE 90.1 compliant
ComfortLink™ microprocessor-based controls
High-efficiency scroll compressor
Quiet, reliable operation
Easy-to-use controls
Energy management module minimizes chiller energy consumption (factory-installed option or field-installed accessory)
Scrolling marquee display shows operating parameters in plain language
Heat recovery capability up to 140°F (60°C)
Reliability Features
Thermostatic expansion valves
Hermetic-type filter driers
Loss of refrigerant charge protection
Low control voltage (to unit) protection
Thermal overload protection
Pressure overload
Electrical overload through the use of definite-purpose contactors and calibrated, ambient compensated, magnetic trip circuit breakers
Standard 60 Hz unit listed with ETL and ETL, Canada, and built in accordance with ASME requirements
Maintenance Features
Over 15 diagnostic functions
Moisture indicating sight glasses
Installation Features
Single point electrical connection
Shipped with R-410A (30MPW ) or nitrogen (30MPA) holding charge
Fits through standard 36-in. doorway
Factory-assembled and shipped with complete internal piping and wiring and essential controls and protective devices
Control power transformer
Standard Warranty
One year parts and labor
Factory-Installed Options
Unit-mounted, non-fused disconnect
Medium temperature brine operation
EMM (energy management module)
Sound enclosure panels
Hot gas bypass
Non-fused disconnect
Medium temperature brine
Mobility package (wheels)
Condenserless unit
Height adjustment (leveling) kit
BACnet Communication
Digital scroll compressor
Water manifold piping
Field-Installed Accessories
EMM (energy management module)
Sound enclosure panels>
Hot gas bypass
Vibration isolators (resilient pads)
Vibration isolators (springs)
BACnet translator
LON (local operating network) translator control
Mobility package (wheels)
Condenser water temperature sensors
Height adjustment (leveling) kit
Compressor return gas sensor
Bronze Y strainer
Navigator™ display module
Remote enhanced display
Vicatualir spacer kit (for water manifold piping)
LEGEND
IPLV = Integrated Part Load Value
AHRI = Air-Conditioning, Heating and Refrigeration Institute
COP = Coefficient of Performance
EER = Energy Efficiency Ratio
IkW = Input Kilowatt
NOTES
1. Rated (60Hz unit) in accordance with AHRI Standard 550/590 at standard rating conditions.
2. Standard rating conditions are as follows:
Cooler Conditions:
Leaving Water Temperature: 44°F (6.7°C)
Flow: 2.4gpm per ton (0.043 L/s per kW)
Condenser Conditions:
Entering Water Temperature: 85°F (29.4°C)
Flow: 3.0gpm per ton (0.054 L/s per kW)
Fouling Factor (Cooler):
0.00010 hr x sq ft x °F per Btuh (0.000018m2 x K per W)
Fouling Factor (Condenser):
0.00025 hr x sq ft x °F per Btuh (0.000044m2 x K per W)
3. IPLV is a single number part load efficiency value calculated from using the efficiency values at 100%, 75%, 50%, and 25% of load when the chiller is operating in AHRI conditions.
4. All data in the above table was generated in Packaged Chiller Builder version 3.39z. Please refer to the most current version of the Packaged Chiller Builder for the most up-to-date data.
5. Contact Carrier for custom ratings.